D4 COMBI
DITER D4 COMBI is a safe and versatile combination device that includes a three-frequency ultrasound device and a versatile two-channel electrotherapy device. The different features of the device can be used separately (also simultaneously) or as a combination treatment.
With a low ultrasound frequency of 0.9 MHz, deep areas can be treated, and with higher frequencies of 2 MHz and 3 MHz, areas closer to the surface of the skin can be treated.
As an electrotherapy device, it is possible to choose different interference, TENS or diadynamic therapy currents.
In combined treatment, the treatment head acts as the second electrode of the circuit and all ultrasound properties can be combined with bipolar interference or TENS.
The device's large and clear display shows simultaneously all the information needed during the treatment, and changing the treatment settings is easy and fast.
* acute injuries and post-injury conditions
* different pain conditions
* gynecological indications
* orthopedic problems caused by chronic stress
* abnormal/painful muscle tension
* non-traumatic symptoms of bones, joints and bursas
* neurological conditions
* soft tissue injuries and diseases
* functional diseases and organic circulatory system diseases, as well as their sequelae
* three ultrasound frequencies
* continuous/pulsed ultrasound
* adjustable pulse ratio and frequency
* interference of four electrodes (with vector automation)
* bipolar interference
* symmetrical biphasic TENS
* monophasic TENS
* selectable constant current or constant voltage treatment in TENS treatment
* TENS treatments: continuous, intermittent, burst and modulated
* rectangular pulse current
* triangular pulse current
* diadynamic currents (MF, DF, CP, CP-id, LP, RS, MM)
* didy current combined with the carrier wave for combined treatments
* galvanic direct current
* galvanic current combined with the carrier wave for combined treatments
* Träbert's 2-5 current
* 9 ready-made diadynamic treatment programs
* I/T diagnostics
* ready-made basic treatment programs, where all settings can be changed by the user
STANDARD TREATMENT HEAD:
THN (6 cm²)
* Frequencies: 0,9 MHz, 2 MHz and 3 MHz
* ERA for above frequencies: 3.5 cm², 4.5 cm² and 5.5 cm²
* Intensity ratio: 1,5
EXTRA TREATMENT HEAD:
THO (1,3 cm²)
* Frequency: 3 MHz
* ERA: 0,5 cm²
* Intensity ratio: 2,6
D4 S COMBI – Most popular!
DITER D4S COMBI is a safe and versatile combination device that includes a three-frequency ultrasound device and a versatile two-channel electrotherapy device. The different features of the device can be used separately (also simultaneously) or as a combination treatment.
With a low ultrasound frequency of 0.9 MHz, deep areas can be treated, and with higher frequencies of 2 MHz and 3 MHz, areas closer to the surface of the skin can be treated.
As an electrotherapy device, it is possible to choose different stimulation, interference, TENS or diadynamic treatment currents.
In combined treatment, the treatment head acts as the second electrode of the circuit and all ultrasound properties can be combined with bipolar interference or TENS.
The device's large and clear display shows simultaneously all the information needed during the treatment, and changing the treatment settings is easy and fast.
* acute injuries and post-injury conditions
* different pain conditions
* gynecological indications
* orthopedic problems caused by chronic stress
* abnormal/painful muscle tension
* non-traumatic symptoms of bones, joints and bursas
* neurological conditions
* soft tissue injuries and diseases
* functional diseases and organic circulatory system diseases, as well as their sequelae
* muscle-activating treatments before surgery
* surgery aftercare
* incontinence
* muscle activation and treatment of spasticity in hemiplegic patients
ULTRASOUND
* three ultrasound frequencies from the same treatment head 0.9 MHz, 2 MHz, and 3 MHz, as well as a small 1.3 cm2 / 3 MHz treatment head available as an accessory
* continuous/pulsed ultrasound
* adjustable pulse ratio and frequency
* the amount of total ultrasound energy (in joules) given to the patient in the treatment area during the treatment can be seen directly on the screen. (Facilitates dosing and monitoring the quality of treatment)
TENS
* symmetrical biphasic TENS
* monophasic TENS
* periodic / continuous / BURST TENS
MNES, (NMES, NMS,) EMS and variable frequency TENS
MICROCURRENT
DIDY
* four separate DIDY currents: traditional DIDY current (MF, DF, CD, CP-id, LP, RS, MM), the same current forms modulated for better skin and electrode transient impedance, DIDY current at 16/32 Hz with traditional with waveforms and modulated.
GALVANIC DIRECT CURRENT
URS current
FARADIC CURRENT
RECTANGULAR AND TRIANGLE CURRENT for electrical irritation studies
IT-CURVE
* is drawn directly on the device's LCD screen while doing examination
9 ready-made diadynamic treatment programs with traditional and modulated current form
INTERFERENCE CURRENTS
* interference currents with four electrodes (vector automation) and three different carrier waves
* 2-electrode medium frequency currents ("two-electrode IF")
STIMULATION CURRENTS
* STIM muscle stimulation currents (MF, variable frequency TENS (NMES, NMS, EMS), RUS (Kotz current), High Voltage)
With all of the above-mentioned currents, it is possible to use the same frequency spectrum as with interference currents, and the rise and fall ramps as well as contraction and rest times can be adjusted separately.
The device has 25 ready-made "treatment cards" in electronic form, with ready-made parameter settings for the treatment of different diagnoses. The user can change all parameter settings, so they are stored in the device's memory. If desired, the device can be restored to the original settings within approx. 5 seconds.
STANDARD TREATMENT HEAD:
THN (6 cm²)
* Frequencies: 0,9 MHz, 2 MHz and 3 MHz
* ERA for above frequencies: 3.5 cm², 4.5 cm² and 5.5 cm²
* Intensity ratio: 1,5
EXTRA TREATMENT HEAD:
THO (1,3 cm²)
* Frequency: 3 MHz
* ERA: 0,5 cm²
* Intensity ratio: 2,6